Duct smoke detector installation location. D4120 duct smoke detector d4s sensor component. Standard location when factory mounted will be on the side opposite the damper actuator. Duct detectors smoke detection nfpa 90a code requirements this article references the current nfpa 90a standard for the installation of air conditioning and ventilating systems. Do not place the detector right next to or over a fireplace or flame producing appliance.
At these locations air flow is less turbulent and the air smoke mixture should be more homogenous refer to nfpa 90a 72 and 101 for more information. Due to smoke dilution in the ducts the duct detectors will respond more slowly than an area detector. Install smoke alarms inside each bedroom outside each sleeping area and on every level of the home including the basement. If the detector is.
It provides basic instruction on the installation of smoke detectors inside the ductwork. Prior to the installation of the damper and smoke detector. The detector may be placed on the ceiling. Nfpa 90a is specific to air conditioning and heating systems installation.
To check the air velocity in the duct. We will show you how to wire a system sensor duct smoke detector to a carrier bryant or icp furnace and then configure it s communicating infinity evoluti. The duct detector should when possible be located a minimum of six duct widths downstream from a source of turbulence bends inlets or deflection plates. 2 6 p n 3101210 rev 02 iss 28jan13.
The inlet sampling tube is to be located between blades to avoid blockage of the airflow past the tube. Designers should also remain aware that duct detectors may not substitute for area smoke detection. Install the duct smoke detector on a flat section of hvac duct between six and ten duct widths from any bends or obstructions. To ensure correct operation install the duct detector using the following guidelines.
The international mechanical code section 606 2 2 also states that unless multiple air han dling systems share common supply or return air ducts or plenums duct detection is not required in the supply air system. On levels without bedrooms install alarms in the living room or den or family room or near the stairway to the upper level or in both locations. In the areas where smoke detectors become inaccessible designers should include smoke detection controls remote from the inaccessible area. 5 2 determine mounting location and configuration on ducts wider than 18 inches it is recommended that the detector be mounted downstream of a bend obstruction in the duct or the supply or return air inlet.